Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
Anchor for fixing thermal insulation with zinc-plated steel screw LX/H
  • Trademark: Starfix
  • Country of origin: Poland
Цена: 0.00 грн.
  • ITB technical assessment
  • Dowel with an extended four-sided expansion zone, for better installation in porous and hollow building materials
  • One screw is used for different dowel lengths (universal screw 6 × 100)
  • Meets the requirements of DSTU B V.2.6-35: 2008, DSTU B V.2.6-36: 2008 and ETAG014
  • In contrast to the dowel for fixing thermal insulation with a metal nail, it does not destroy the walls in the hollow base material when hooking the screw
  • Universal for use in all base materials
  • The perforated surface of the disc facilitates plaster work and guarantees high quality adhesion to the plaster.
  • Retains properties over a wide temperature range

Code

Diameter (drilling) nailed-in plastic anchor, mm

Nailed-in plastic anchor length, mm

Pressure disk diameter, mm

Thrust length, mm

Minimum installation depth, mm

Maximum thermal insulation thickness, mm

Minimum drilling depth for through installation, mm

Quantity per package, pcs

LX 10 160 H

10

160

60

80

601)/402)

1001)/1202)

170

100

LX 10 180 H

10

180

60

80

601)/402)

1201)/1402)

190

100

LX 10 200 H

10

200

60

80

601)/402)

1401)/1602)

210

100

LX 10 220 H

10

220

60

80

601)/402)

1601)/1802)

230

100

LX 10 240 H

10

240

60

80

601)/402)

1801)/2002)

250

100

1) for all base materials except hollow ceramic bricks
2) for hollow ceramic bricks

Estimated pull-out load:
from concrete - 1.5 kN
from solid red brick - 1.5 kN
from solid silicate brick - 1.5 kN
from a hollow ceramic block - 1.1 kN
from aerated concrete - 0.6 kN
Recommended for plaster facades and facades with a ventilated air layer.
For fixing such heat-insulating materials:
  • Styrofoam
  • Mineral wool
  • Styrofoam
  • Glass wool

Foundation materials



Characteristics
Length of spacing zone, mm80
Nail materialself-tapping screw
For fixing mineral woolyes
For fixing foamyes
For plaster facadeyes
For ventilated facadeyes
  • Type of installation - push-through installation
  • For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
  • Recommended mounting parameters:
  • minimum base thickness - 100 mm
  • minimum center distance between dowels - 100 mm
  • minimum distance from the edge of the base to the dowel - 100 mm
  • Installation instructions: