![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/ati-tze/xatieta-484x486w.jpg.pagespeed.ic.QW_2guTKPn.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/ati-tze/xatitze1-484x486w.jpg.pagespeed.ic.4Wn7U2fHgZ.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/ati-tze/xatitze3-484x486w.jpg.pagespeed.ic.JqyfxKyrIq.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/xeasyfix3-484x486w.jpg.pagespeed.ic.ZVGTMDO-Te.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/ati-tze/xatieta-63x63.jpg.pagespeed.ic.z6yljILrEx.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/ati-tze/xatitze1-63x63.jpg.pagespeed.ic.TSgjlh_1Ae.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/ati-tze/xatitze3-63x63.jpg.pagespeed.ic.acgNLsCQeU.jpg)
![Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE](https://amex.ua/image/cache/catalog/products/xeasyfix3-63x63.jpg.pagespeed.ic.iVYVYohcqH.jpg)
- Trademark: EasyFix
- Country of origin: Ukraine
- European Technical Assessment ETA 22/0349
- Extended expansion zone - 90 mm, for better fixing of dowels in hollow materials, aerated concrete and foam concrete
- Extended thermal head (30 mm) prevents cold bridges and protects the nail from moisture penetration
- Meets the requirements of EAD 330196-01-0604, DSTU B V.2.6-35: 2008, DSTU B V.2.6-36: 2008 and ETAG014
- The shape of the expansion zone has been optimized for better installation in building materials
- Universal for use in all base materials
- The perforated surface of the disc facilitates plaster work and guarantees high quality adhesion to the plaster.
- Retains properties over a wide temperature range
Code | Diameter (drilling) nailed-in plastic anchor, mm | Nailed-in plastic anchor length, mm | Pressure disk diameter, mm | Thrust length, mm | Minimum installation depth, mm | Maximum thermal insulation thickness, mm | Minimum drilling depth for through installation, mm | Quantity per package, pcs. |
ATI 10 120 TZE | 10 | 120 | 60 | 70 | 50 | 70 | 130 | 300 |
ATI 10 140 TZE | 10 | 140 | 60 | 70 | 50 | 90 | 150 | 250 |
ATI 10 160 TZE | 10 | 160 | 60 | 70 | 50 | 110 | 170 | 200 |
ATI 10 180 TZE | 10 | 180 | 60 | 90 | 50 | 130 | 190 | 200 |
ATI 10 200 TZE | 10 | 200 | 60 | 90 | 50 | 150 | 210 | 150 |
ATI 10 220 TZE | 10 | 220 | 60 | 90 | 50 | 170 | 230 | 150 |
ATI 10 240 TZE | 10 | 240 | 60 | 90 | 50 | 190 | 250 | 100 |
ATI 10 260 TZE | 10 | 260 | 60 | 90 | 50 | 210 | 270 | 100 |
ATI 10 300 TZE | 10 | 300 | 60 | 90 | 50 | 250 | 310 | 100 |
Estimated pull-out load:
from concrete - 1.0 kN
from solid red brick - 1.0 kN
from solid silicate brick - 1.0 kN
from a hollow ceramic block - 0.7 kN
from aerated concrete - 0.7 kN
Recommended for plaster facades and facades with a ventilated air layer.
For fixing such heat-insulating materials:
- Styrofoam
- Mineral wool
- Styrofoam
- Glass wool
Foundation materials
Characteristics | |
Length of spacing zone, mm | 90 |
Nail material | steel |
For fixing mineral wool | yes |
For fixing foam | yes |
For plaster facade | yes |
For ventilated facade | yes |
- Type of installation - push-through installation
- For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
- Recommended mounting parameters:
- minimum base thickness - 100 mm
- minimum center distance between dowels - 100 mm
- minimum distance from the edge of the base to the dowel - 100 mm
- Installation instructions:
- 1. Drill a hole
- 2-3. Hammer to the stop, hitting the body of the dowel with a hammer
- 4-5. Hammer the spacer (nail) flush with the dowel