Anchor for fixing thermal insulation with elongated expansion zone and polyamide rod LDK/GZN

 Anchor for fixing thermal insulation with elongated expansion zone and  polyamide rod  LDK/GZN
 Anchor for fixing thermal insulation with elongated expansion zone and  polyamide rod  LDK/GZN
 Anchor for fixing thermal insulation with elongated expansion zone and  polyamide rod  LDK/GZN
 Anchor for fixing thermal insulation with elongated expansion zone and  polyamide rod  LDK/GZN
Anchor for fixing thermal insulation with elongated expansion zone and polyamide rod LDK/GZN
  • Trademark: Starfix
  • Country of origin: Poland
Цена: 0.00 грн.
  • European Technical Assessment ETA
  • ITB technical assessment
  • Meets the requirements of DSTU B V.2.6-35: 2008, DSTU B V.2.6-36: 2008 and ETAG014
  • Extended thrust zone - 80mm
  • The shape of the expansion zone has been optimized for better installation in building materials
  • The perforated surface of the disc facilitates plaster work and guarantees high quality adhesion to the plaster.
  • Certified for use in all substrate categories A, B, C, D, E.

Code

Diameter (drilling) nailed-in plastic anchor, mm

Nailed-in plastic anchor length, mm

Pressure disk diameter, mm

Thrust length, mm

   Minimum installation depth, mm

Maximum thermal insulation thickness, mm

Minimum drilling depth for through installation, mm

Quantity per package, pcs.

LDK 10 120 GZN

10

120

60

80

50

70

130

300

LDK 10 160 GZN

10

160

60

80

50

110

170

200

LDK 10 180 GZN

10

180

60

80

50

130

190

200

LDK 10 220 GZN

10

220

60

80

50

170

230

150

LDK 10 240 GZN

10

240

60

80

50

190

250

100

LDK 10 260 GZN

10

260

60

80

50

210

270

100

 Расчетная нагрузка на вырывание :
 c бетона - 0,4 kN
 с полнотелого красного кирпича - 0,2 kN
 с полнотелого силикатного кирпича - 0,2 kN
 с пустотелого керамического блока - 0,2 kN
 с газобетона - 0,2 kN

Recommended for plaster facades and facades with a ventilated air layer.
For fixing such heat-insulating materials:
  • Styrofoam
  • Mineral wool
  • Styrofoam
  • Glass wool

Foundation materials



Characteristics
Length of spacing zone, mm80
Nail materialpolyamide
For fixing mineral woolyes
For fixing foamyes
For plaster facadeyes
For ventilated facadeyes

  • Type of installation - push-through installation
  • For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
  • Recommended mounting parameters:
  • minimum base thickness - 100 mm
  • minimum center distance between dowels - 100 mm
  • minimum distance from the edge of the base to the dowel - 100 mm
  • Installation instructions:
  • 1. Drill a hole
  • 2-3. Hammer to the stop, hitting the body of the dowel with a hammer
  • 4-5. Hammer the spacer (nail) flush with the dowel