Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN

 Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
 Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
 Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
 Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
 Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
 Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
Anchor for fixing thermal insulation with elongated expansion zone and metal nail LZK/TN
  • Торговая марка: EasyFix
  • Страна происхождения: Україна
Цена: 0.00 грн.
  • Отвечает требованиям ДСТУ Б В.2.6-35: 2008 и ETAG014
  • Удлинённая зона распора - 80мм
  • Оптимизирована форма зоны распора для лучшей установки в строительные материалы
  • Перфорированная поверхность диска способствует облегчению штукатурных работ и гарантирует высокое качество сцепления со штукатуркой

Code

Diameter (drilling) nailed-in plastic anchor, mm

Nailed-in plastic anchor length, mm

Pressure disk diameter, mm

Thrust length, mm

  Minimum installation depth, mm

Maximum thermal insulation thickness, mm

Minimum drilling depth for through installation, mm

Quantity per package, pcs.

LZK 10 80 TN

10

80

60

50

50

30

90

100

LZK 10 100 TN

10

100

60

50

50

50

110

100

LZK 10 120 TN

10

120

60

50

50

70

130

100

LZK 10 140 TN

10

140

60

50

50

90

150

100

LZK 10 160 TN

10

160

60

80

50

110

170

50

LZK 10 180 TN

10

180

60

80

50

130

190

50

LZK 10 200 TN

10

200

60

80

50

150

210

50

 Estimated pull-out load:
from concrete - 0.75 kN
from solid red brick - 0.75 kN
from solid silicate brick - 0.75 kN
from a hollow ceramic block - 0.30 kN
from aerated concrete - 0.60 kN

Recommended for facades with ventilated air space.

For fixing such heat-insulating materials:

  • Mineral wool
  • Glass wool

    Foundation materials

Characteristics
Длинна распорной зоны, мм80
Материал гвоздясталь
Для крепления минеральной ватыда
Для крепления пенопластада
Для вентилируемого фасадада
  • Type of installation - push-through installation
  • For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
  • Recommended mounting parameters:
  • minimum base thickness - 100 mm
  • minimum center distance between dowels - 100 mm
  • minimum distance from the edge of the base to the dowel - 100 mm
  • Installation instructions:
  • 1. Drill a hole
  • 2-3. Hammer to the stop, hitting the body of the dowel with a hammer
  • 4-5. Hammer the spacer (nail) flush with the dowel