Anchor for fixing thermal insulation with a metal nail and a thermal head LFH/TZ

Anchor for fixing thermal insulation with a metal nail and a thermal head LFH/TZ
Anchor for fixing thermal insulation with a metal nail and a thermal head LFH/TZ
Anchor for fixing thermal insulation with a metal nail and a thermal head LFH/TZ
Anchor for fixing thermal insulation with a metal nail and a thermal head LFH/TZ
Anchor for fixing thermal insulation with a metal nail and a thermal head LFH/TZ
  • Trademark: Starfix
  • Country of origin: Poland
Цена: 0.00 грн.
  • ITB technical assessment
  • Meets the requirements of DSTU B V.2.6-35: 2008, DSTU B V.2.6-36: 2008 and ETAG014
  • Specially shaped thrust zone for fast installation in solid materials
  • The perforated surface of the disc facilitates plaster work and guarantees high quality adhesion to the plaster.
  • The special thermal head prevents the formation of a cold bridge and protects the rod from moisture penetration.

Code

Diameter (drilling) nailed-in plastic anchor, mm

Nailed-in plastic anchor length, mm

Pressure disk diameter, mm

Thrust length, mm

  Minimum installation depth, mm

Maximum thermal     insulation thickness, mm

Minimum drilling depth for through installation, mm

Quantity per package, pcs.

LFH 10 160 TZ

10

160

60

50

50

110

170

200

LFH 10 180 TZ

10

180

60

50

50

130

190

200

LFH 10 200 TZ

10

200

60

50

50

150

210

150

LFH 10 220 TZ

10

220

60

50

50

170

230

150

LFH 10 240 TZ

10

240

60

50

50

190

250

100

LFH 10 260 TZ

10

260

60

50

50

210

270

100

 Estimated pull-out load:

from concrete - 0.75 kN
from solid red brick - 0.75 kN
from solid silicate brick - 0.75 kN
from aerated concrete - 0.60 kN

Recommended for plaster facades and facades with a ventilated air layer.

For fixing such heat-insulating materials:

  • Styrofoam
  • Mineral wool
  • Styrofoam
  • Glass wool

Foundation materials



Characteristics
Length of spacing zone, mm50
Nail materialsteel
For fixing mineral woolyes
For fixing foamyes
For plaster facadeyes
For ventilated facadeyes

  • Type of installation - push-through installation
  • For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
  • Recommended mounting parameters:
  • minimum base thickness - 100 mm
  • minimum center distance between dowels - 100 mm
  • minimum distance from the edge of the base to the dowel - 100 mm
  • Installation instructions:
  • 1. Drill a hole
  • 2-3. Hammer to the stop, hitting the body of the dowel with a hammer
  • 4-5. Hammer the spacer (nail) flush with the dowel