Menu
Корзина

Anchor for fixing thermal insulation with elongated expansion zone and metal nail and thermal head LDK/TZ

Anchor for fixing thermal insulation with elongated expansion zone and metal nail  and thermal head LDK/TZ
Anchor for fixing thermal insulation with elongated expansion zone and metal nail  and thermal head LDK/TZ
Anchor for fixing thermal insulation with elongated expansion zone and metal nail  and thermal head LDK/TZ
Anchor for fixing thermal insulation with elongated expansion zone and metal nail  and thermal head LDK/TZ
Anchor for fixing thermal insulation with elongated expansion zone and metal nail  and thermal head LDK/TZ
Anchor for fixing thermal insulation with elongated expansion zone and metal nail  and thermal head LDK/TZ
Anchor for fixing thermal insulation with elongated expansion zone and metal nail and thermal head LDK/TZ
  • Trademark: Starfix
  • Country of origin: Poland
Цена: 0.00 грн.
  • European Technical Assessment ETA
  • ITB technical assessment
  • Meets the requirements of DSTU B V.2.6-35: 2008, DSTU B V.2.6-36: 2008 and ETAG014
  • Extended thrust zone - 80mm
  • The shape of the expansion zone has been optimized for better installation in building materials
  • The special thermal head prevents the formation of a cold bridge and protects the rod from moisture penetration.
  • The perforated surface of the disc facilitates plaster work and guarantees high quality adhesion to the plaster.
  • Certified for use in all substrate categories A, B, C, D, E.
  • Exclusive dowel lengths 340mm, 380mm, 420mm

Code

Diameter (drilling) nailed-in plastic anchor, mm

Nailed-in plastic anchor length, mm

Pressure disk diameter, mm

Thrust length, mm

  Minimum installation depth, mm

Maximum thermal insulation thickness, mm

Minimum drilling depth for through installation, mm

Quantity per package, pcs.

LDK 10 80 TZ

10

80

60

50

50

30

90

400

LDK 10 100 TZ

10

100

60

50

50

50

110

350

LDK 10 120 TZ

10

120

60

80

50

70

130

300

LDK 10 140 TZ

10

140

60

80

50

90

150

250

LDK 10 160 TZ

10

160

60

80

50

110

170

200

LDK 10 180 TZ

10

180

60

80

50

130

190

200

LDK 10 200 TZ

10

200

60

80

50

150

210

150

LDK 10 220 TZ

10

220

60

80

50

170

230

150

LDK 10 240 TZ

10

240

60

80

50

190

250

100

LDK 10 260 TZ

10

260

60

80

50

210

270

100

LDK 10 280 TZ

10

280

60

80

50

230

290

100

LDK 10 300 TZ

10

300

60

80

50

250

310

100

LDK 10 340 TZ

10

340

60

80

50

290

350

100

LDK 10 380 TZ

10

380

60

80

50

330

390

50

LDK 10 420 TZ

10

420

60

80

50

370

430

50

Estimated pull-out load:
from concrete - 0.75 kN
from solid red brick - 0.75 kN
from solid silicate brick - 0.75 kN
from a hollow ceramic block - 0.30 kN
from aerated concrete - 0.60 kN

Recommended for plaster facades and facades with a ventilated air layer.
For fixing such heat-insulating materials:
  • Styrofoam
  • Mineral wool
  • Styrofoam
  • Glass wool

Foundation materials



Characteristics
Length of spacing zone, mm80
Nail materialsteel
For fixing mineral woolyes
For fixing foamyes
For plaster facadeyes
For ventilated facadeyes

  • Type of installation - push-through installation
  • For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
  • Recommended mounting parameters:
  • minimum base thickness - 100 mm
  • minimum center distance between dowels - 100 mm
  • minimum distance from the edge of the base to the dowel - 100 mm
  • Installation instructions:
  • 1. Drill a hole
  • 2-3. Hammer to the stop, hitting the body of the dowel with a hammer
  • 4-5. Hammer the spacer (nail) flush with the dowel