Menu
Корзина

Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE

 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
 Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head  ATI/TZE
Anchor for fixing thermal insulation with metal nail and elongated expansion zone and elongated thermal head ATI/TZE
  • Trademark: EasyFix
  • Country of origin: Ukraine
Цена: 0.00 грн.
  • European Technical Assessment ETA 22/0349
  • Extended expansion zone - 90 mm, for better fixing of dowels in hollow materials, aerated concrete and foam concrete
  • Extended thermal head (30 mm) prevents cold bridges and protects the nail from moisture penetration
  • Meets the requirements of EAD 330196-01-0604, DSTU B V.2.6-35: 2008, DSTU B V.2.6-36: 2008 and ETAG014
  • The shape of the expansion zone has been optimized for better installation in building materials
  • Universal for use in all base materials
  • The perforated surface of the disc facilitates plaster work and guarantees high quality adhesion to the plaster.
  • Retains properties over a wide temperature range

Code

Diameter (drilling) nailed-in plastic anchor, mm

Nailed-in plastic anchor length, mm

Pressure disk diameter, mm

Thrust length, mm

  Minimum installation depth, mm

Maximum thermal insulation thickness, mm

Minimum drilling depth for through installation, mm

Quantity per package, pcs.​

ATI 10 120 TZE

10

120

60

70

50

70

130

300

ATI 10 140 TZE

10

140

60

70

50

90

150

250

ATI 10 160 TZE

10

160

60

70

50

110

170

200

ATI 10 180 TZE

10

180

60

90

50

130

190

200

ATI 10 200 TZE

10

200

60

90

50

150

210

150

ATI 10 220 TZE

10

220

60

90

50

170

230

150

ATI 10 240 TZE

10

240

60

90

50

190

250

100

ATI 10 260 TZE

10

260

60

90

50

210

270

100

ATI 10 300 TZE

10

300

60

90

50

250

310

100

Estimated pull-out load:
from concrete - 1.0 kN
from solid red brick - 1.0 kN
from solid silicate brick - 1.0 kN
from a hollow ceramic block - 0.7 kN
from aerated concrete - 0.7 kN

Recommended for plaster facades and facades with a ventilated air layer.
For fixing such heat-insulating materials:
  • Styrofoam
  • Mineral wool
  • Styrofoam
  • Glass wool

Foundation materials



Characteristics
Length of spacing zone, mm90
Nail materialsteel
For fixing mineral woolyes
For fixing foamyes
For plaster facadeyes
For ventilated facadeyes
  • Type of installation - push-through installation
  • For installation in aerated concrete, foam concrete, shell rock and ceramic hollow block, it is recommended to use only drilling without impact
  • Recommended mounting parameters:
  • minimum base thickness - 100 mm
  • minimum center distance between dowels - 100 mm
  • minimum distance from the edge of the base to the dowel - 100 mm
  • Installation instructions:
  • 1. Drill a hole
  • 2-3. Hammer to the stop, hitting the body of the dowel with a hammer
  • 4-5. Hammer the spacer (nail) flush with the dowel